Combine cold light cables and adapters
In short: A cold light cable is determined by three specifications: diameter, length and the two adapter at its ends. One is attached to the light source, the other to the instrument. Both are screwed on and can be replaced.
1. The cable: diameter and length
The cables are universal fiber optic cables with bonded fibers, manufactured in Germany and autoclavable at 134 °C. They are designed for standard halogen light sources.
| diameter | Lengths | Application |
|---|---|---|
| 3.5 mm | 180 to 500 cm | finer instruments, lower luminous flux |
| 4.8 mm | 180 to 500 cm | Standard, higher luminous flux |
The length depends on the distance between the light source and the work area. Cables that are too long get in the way, while those that are too short force you to reposition the light source.
2. The two adapter sides
The adapter system allows one cable to be used with multiple devices. Instead of having a separate cable for each combination, you simply screw on the appropriate adapter.
| Page | Suitable for |
|---|---|
| Instrument side | Codman, Stryker Headlight, Storz, Olympus (also new version), Aesculap, Wolf with clip and snap closure, Schott, Zeiss, ACM British with clip and snap |
| Light source side | Zeiss, Kaps and Schott as step adapters, Zeiss OPMI, ACM British, Codman, Fuji |
When dealing with Wolf and ACM British cameras, pay attention to the type of closure: Clip and Snap look similar, but are not the same. Olympus also offers an older and a newer version.
3. Three steps to the right combination
- Determine the light source. The manufacturer and model determine the adapter required for the source side.
- Determine the instrument. The adapter for the instrument side is determined by whether it's an endoscope, headlight, or microscope.
- Select cable. Diameter according to the instrument, length according to the working distance.
4. Frequently Asked Questions
- Do I need a separate cold light cable for each device?
- No. The adapter system allows you to use one cable with different light sources and instruments. You simply screw on the appropriate adapter and change it as needed. This saves on cable and simplifies inventory management.
- What is the difference between 3.5 and 4.8 mm?
- The diameter of the fiber bundle. A thicker bundle transmits more light, a thinner one is suitable for finer instruments. The instrument dictates the required diameter.
- Are the cables autoclavable?
- Yes, at 134 °C. Observe the manufacturer's reprocessing instructions for your instrument and the number of permissible cycles.
- What is the difference between Clip and Snap adapters for Wolf adapters?
- There are two different types of connectors that look similar. We stock them separately. Before ordering, please check which type is installed on your existing cable or instrument.
- Which length should I choose?
- As short as possible, as long as necessary. Available in lengths of 180, 230, 300, 350, 400, and 500 cm. Measure the distance between the light source and the work area in the setup you actually use.
- Do the adapters also fit older light sources?
- Often yes, the product range also covers older systems like the Zeiss OPMI. Tell us the manufacturer and model of your light source and instrument, and we'll check the compatibility.
5. Assignment by nib
Tell us what light source and instrument you have, or send us photos of the two connections. We will put together the appropriate combination of cables and adapters and give you a price quote.
Telephone 02363 3663-0 · kontakt@nispel.de · Request for quotation
Last updated: August 25, 2026. The information is taken from the manufacturer's documentation for the items in our product range. In case of doubt, the instruction manual for your device is binding.